Send Message
Lanry Instruments (Shanghai) Co., Ltd.

Lanry Instruments (Shanghai) Co., Ltd.

 

Specialize In Ultrasonic Flowmeter More Than 20 Years!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsInsertion Ultrasonic Flow Meter

High Accuracy Insertion Ultrasonic Flow Meter , Digital Fluid Flow Meter

High Accuracy Insertion Ultrasonic Flow Meter , Digital Fluid Flow Meter

  • High Accuracy Insertion Ultrasonic Flow Meter , Digital Fluid Flow Meter
High Accuracy Insertion Ultrasonic Flow Meter , Digital Fluid Flow Meter
Product Details:
Place of Origin: Shanghai, China (Mainland)
Brand Name: Lanry
Certification: CE
Model Number: TF1100-EI
Payment & Shipping Terms:
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Carton Packing
Supply Ability: 100unit/week
Contact Now
Detailed Product Description
Product Name: High Accuracy Insertion Digital Flow Meter Output: Datalogger/4-20mA /OCT /RS485/RS232/GPRS
Accuracy: Reading+/- 1% Transducer Type: Insertion
Application: Measuring Liquids Single Package: 44*33*21cm
High Light:

insertion type ultrasonic flow meter

,

digital ultrasonic flow meter

High accuracy insertion digital flow meter TF1100-EI with ultrasonic sensor
 
Welcome to use new generation High accuracy Insertion digital flow meter TF1100-EI, please read the user manual carefully before using. The High accuracy Inline digital flow meter TF1100-EI is designed to be used to the measurement of flow within full pipes for long-term flow measurement.
Inserted Type Ultrasonic Flow Meter provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
 
High accuracy insertion digital flow meter TF1100-EI with ultrasonic sensor Features:
 
1. Hot-tapped installation, no pipe line flow interrupted
2. Wide liquid temperature range: -35℃~200℃.
3. Data logger function for insertion ultrasonic flow meter
4. Thermal energy measurement capability can be optional.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Wide bi-directional flow range of 0.01 m/s to 12 m/s..

7. Degree of protection: IP66 according to EN60529

 

Application
 

General
● Service and maintenance

● Replacement of defective devices

● Support of commissioning process and installation

● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

● Energy efficiency audits

 

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

 
High Accuracy Insertion Ultrasonic Flow Meter , Digital Fluid Flow Meter 0
 

Specifications:Transmitter

 

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -20℃ to +60℃
Housing material Fiberglass
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Communication 4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
Security Keypad lockout, system lockout
Size 244*196*144mm
Weight 2.4kg

 

Specifications:Transducer

 

Degree of protection IP67 or IP68 according to EN60529
Suited Liquid Temperature Std. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Pipe diameter range DN65-6000
Transducer Size Type S Φ58*199mm
Material of transducer Stainless Steel
Cable Length Std: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 

 

Packing & Delivery

 

High accuracy insertion digital flow meter TF1100-EI with ultrasonic sensor

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 
High Accuracy Insertion Ultrasonic Flow Meter , Digital Fluid Flow Meter 1High Accuracy Insertion Ultrasonic Flow Meter , Digital Fluid Flow Meter 2High Accuracy Insertion Ultrasonic Flow Meter , Digital Fluid Flow Meter 3

Delivery

High accuracy insertion digital flow meter TF1100-EI with ultrasonic sensor

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Contact Details
Lanry Instruments (Shanghai) Co., Ltd.

Contact Person: Ms. Tracy Xu

Tel: 86-021-67618991

Fax: 86-021-67801625

Send your inquiry directly to us (0 / 3000)