Lanry Instruments (Shanghai) Co., Ltd.
Specialize In Ultrasonic Flowmeter More Than 20 Years!
Place of Origin: | China |
Brand Name: | Lanry |
Certification: | ISO9000, CE, CPA,CMC |
Model Number: | TF1100-CH |
Minimum Order Quantity: | 1 Unit |
---|---|
Price: | Negotiable |
Packaging Details: | carton packing 44X33X22cm 1PC/carton |
Delivery Time: | 7-10 working days |
Payment Terms: | T/T |
Supply Ability: | 1000pcs/month |
Flow Velocity Range: | 0.01 To 12m/s, Bi-directional | Type: | Handheld |
---|---|---|---|
Response Time: | 0.5s | Power Supply: | AC:85-265V Up To 14 Hours With Fully Charged Internal Batteries |
Communication: | OCT, RS232 ,Logged Data | Degree Of Protection: | IP68 |
High Light: | ultrasonic liquid flow meter,high temperature ultrasonic flow meter |
Flow Rate Calibration Ultrasonic Flow Measurement TF1100-CH
Transit-time Ultrasonic Flow Meter work with method. The 14 hours battery can be recharged, The back-lit 4 lines display makes the readings more intuitive. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.
User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy-to-use flow meter is an ideal tool to support service and maintenance activities.It can also be used for the control or even for the temporary replacement of permanently installed meters.
Flow Rate Calibration Ultrasonic Flow Measurement TF1100-CH Features:
1)Can be used for mobile measurement, flow rate calibration, data comparing, meters running status checking.
2)Non-invasive transducers.
3)Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.
4)Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.
Flow Rate Calibration Ultrasonic Flow Measurement Applications:
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.
General
● Support of commissioning process and installation
● Service and maintenance
● Replacement of defective devices
● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves
Specifications: Transmitter
Measurement principle | Ultrasonic transit-time difference correlation principle |
Flow velocity range | 0.01 to 12 m/s, bi-directional |
Resolution | 0.25mm/s |
Repeatability | 0.2% of reading |
Accuracy | ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s |
Response time | 0.5s |
Sensitivity | 0.003m/s |
Damping of displayed value | 0-99s(selectable by user) |
Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
Power Supply | AC: 85-265V Up to 14 h with fully charged internal batteries |
Enclosure type | Handheld, Portable |
Degree of protection | IP65 according to EN60529 |
Housing material | ABS( UL 94HB) |
Operating temperature | -20℃ to +60℃ |
Display | 4 line×16 English letters LCD graphic display, backlit |
Units | User Configured (English and Metric) |
Rate | Rate and Velocity Display |
Specifications: Transducer
Degree of protection | IP65 according to EN60529.(IP67 or IP68 Upon request) |
Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
High Temp.: -35℃~200℃ for short periods up to 250℃ | |
Transducer Size | Type S 48(h)*28(w)*28(d)mm |
Type M 60(h)*34(w)*33(d)mm | |
Type L 80(h)*40(w)*42(d)mm | |
Material of transducer | Aluminum for standard temp. sensor, and peek for high temp. sensor |
Cable Length | Std: 5m |
Data sheet download TF1100-CH transit-time handheld ultrasonic flowmet...
Manual Download TF1100-CH transit-time handheld flowmeter Manual.p...
Dimensional Sketches
Transmitter:
Transducer:
Packing & Delivery
Clamp On Handheld Ultrasonic Flow Meter TF1100-CH for water and chilled water application
Standard meter: 3-7 days
Special meter: pls contact us
Express, by air, by sea can be optional.
Contact Person: Ms. Tracy Xu
Tel: 86-021-67618991
Fax: 86-021-67801625
ultrasonic flow meter of Chemical industry application
Intrusive Ultrasonic Inline Ultrasonic Flow Meter
Inserted Type Transit Time Flow Meter TF1100-EI With High Temperature Sensor
Clamp On Transit Time Ultrasonic Flow Meter , Portable Transit Time Flow Meter
Outdoor Ultrasonic Liquid Flow Meter High Accuracy For Hot / Cooling Water
Home / Industrial Water Flow Meter Stable Wide Measuring Range Ratio
White Ultrasonic Water Meter Low Starting Flow Rate Strong Anti - Interference
High Durability Ultrasonic Water Meter low cost Ultrasonic Water Meter
Area Velocity Flow Meter DOF6000-W For open channel and Partially Filled Pipe
Energy Saving Portable Ultrasonic Water Flow Meter For Area Velocity Measurement
IP68 Area Velocity Flow Meter High Precision 16GB Data Logger With GPRS Output
4-20mA Portable Doppler Ultrasonic Flow Meters For 200-6000mm Open Channel