Product Details:
Place of Origin: Shanghai, China (Mainland)
Brand Name: Lanry
Certification: CE
Model Number: TF1100-EI
Payment & Shipping Terms:
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Carton Packing
Supply Ability: 100unit/week
Contact Now
Detailed Product Description
Resolution: 0.25mm/s Power Supply: AC:85-265V DC:24V/500mA
Sensitivity: 0.003m/s Application: Measuring Liquids
Transducer Range: DN20-DN6000 Repeatability: 0.2%reading
High Light:

ultrasonic liquid flow meter

,

high temperature ultrasonic flow meter

 
No pressure drop Insertion Transit Time Ultrasonic Flow Meter for DN65 to DN6000mm
 
Insertion Ultrasonic Liquid Flow Meter For DN65-6000 0
TF1100-EI transit-time Insertion ultrasonic flowmeter provides abundant capabilities for accurate liquid flow measurement from outside of
a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The
proprietary signal quality tracking and  self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
 
No pressure drop Insertion Transit Time Ultrasonic Flow Meter for DN65 to DN6000mm Features:
1. No moving parts, no pressure drop, no maintenance.
2. The heat measurement function by configuring with paired temperature sensors.
3. Data logger function.
4. High temp. Insertion tansducers are suitable for high temperature of -35℃~150℃.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.
6. Wide bi-directional flow range of 0.01 m/s to 12 m/s.

 

Application
 

General

● Replacement of defective devices

● Support of commissioning process and installation

● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

● Energy efficiency audits

 

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

 
Insertion Ultrasonic Liquid Flow Meter For DN65-6000 1
 

Specifications:Transmitter

 

Measurement principle Ultrasonic transit-time difference correlation principle
Resolution 0.25mm/s
Flow velocity range 0.01 to 12 m/s, bi-directional
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -20℃ to +60℃
Housing material Fiberglass
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy unit GJ,KWh can be optional
Communication 4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
Security Keypad lockout, system lockout

 

Specifications:Transducer

 

Degree of protection IP67 or IP68 according to EN60529
Suited Liquid Temperature High Temp.: -35℃~150℃
Std. Temp.: -35℃~85℃
Pipe diameter range DN65-6000
Transducer Size Type S Φ58*199mm
Material of transducer Stainless Steel
Cable Length Std: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 

 

Packing & Delivery

 

Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 
Insertion Ultrasonic Liquid Flow Meter For DN65-6000 2Insertion Ultrasonic Liquid Flow Meter For DN65-6000 3Insertion Ultrasonic Liquid Flow Meter For DN65-6000 4

Delivery

Inserted Type Ultrasonic Flow Meter With 4-20mA Output 

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Contact Details
Lanry Instruments (Shanghai) Co., Ltd.

Contact Person: Ms. Tracy Xu

Tel: 86-021-67618991

Fax: 86-021-67801625

Send your inquiry directly to us (0 / 3000)